Application
ESD tiles are widely used in clean room, manufacturing & assembly workshops of electronic products, hospitals, data center & computer room, and other areas that require anti-static or conductive environment
Characteristics
- Permanent conductive properties
- Excellent dimension stability
- More patterns for better decorative effect
- Improved ware and ease of maintenance
- Fireproof, waterproof and corrosion protection
Test Parameter
Item | Standard | Data | |
Electrical Resistance(Ω)
|
SJ/T11236-2001 | Conductive EC 2.5*104-1.0*106 |
Dispassive SD 1.0*106-109 |
EN1081 | Conductive EC 104-106 |
Dispassive SD 106-109 |
|
Statiing Voltage
|
SJ/T11236-2001 | 50V | 100V |
AATCC-134 | |V|<100V | ||
Static Decay(s)
|
GJB2605-1996 | ≤2 | |
FTM1080-4046 | 0.01 | 0.01 | |
Wear Resistance | SJ/T11236-2001 | ≤0.020 g/cm2 | |
ASTM D1044-13 | Circle: 2500 Gauge loss(%): 0.48 |
Circle: 5000 Gauge loss(%): 0.95 |
|
Fire Resistance | SJ/T11236-2001 | FV-0 | |
EN13501-1 | Bfl-s1 | ||
Slip Resistance Wet | DIN 51130 | R9 | |
EN13893 | ≥0.3 | ||
Residual Concavity
|
SJ/T11236-2001 | ≤0.15 | |
EN433 | 0.03 | ||
Color Fastness | ISO 105B 02 | ≥6 | |
Chemical Products Resistance | EN ISO 26987:2012 | OK | |
Toxic Texting | EN 71-3 | OK | |
GB 18586-2001 | |||
TVOC After 28 Days(μg/m³) | ISO 16000-3 | <10 |